HOME > ȯ°æ¼³ºñ > Scrubber > Venturi Scrubber |
|
Venturi Scrubber À̶õ? |
|
½À½ÄÁýÁøÀåÄ¡ÀÇ ÀÏÁ¾À¸·Î, ÇÔÁø°¡½º¸¦ ½º·ÎÆ®ºÎ¿¡¼ 60~90m/sec·Î °í¼Ó ºÐ»çÇÏ¿© ÀÛÀº ¹°¹æ¿ï·Î Á¢ÃËÇÏ¿© ºÐÁøÀ» ºÐ¸® Á¦°Å |
|
°¡Àå ÀûÇÕÇÑ ¹°¹æ¿ïÀº ºÐÁø ÀÔÀÚ°æÀÇ ¾à 150¹èÀ̸ç, Æ÷Áý ÀÔÀÚ¿¡ µû¶ó ¼³°è ½Ã À¯¼® ¹×, ±â¾×ºñ¸¦ ¼±Åà Àû¿ë |
|
½º·ÎÆ®ºÎ¸¦ Åë°úÇÑ Ã»Á¤ °¡½ºÀÇ mist Á¦°Å¸¦ À§ÇÏ¿© ÀÏÁ¤°ø°£ÀÌ ÇÊ¿äÇϹǷΠÅë»ó cycloneÀ» ¼³Ä¡ÇÏ¿© Demister·Î »ç¿ë |
|
Fume gas¸¦ µ¿¹ÝÇÑ ÇÔÁø°¡½º¸¦ 󸮽ô Packed tower¸¦ ÈÄ´Ü¿¡ ¼³Ä¡ÇÏ¿© Fume ¹× ºÐÁø Á¦°Å È¿°ú Áõ´ë |
|
Ư¡ |
|
¼³Ä¡ °ø°£ ÀÛ°í Á¦ÀÛÀÌ °£´ÜÇÏ¿© ÅõÀÚºñ¿ëÀÌ Àú·Å |
|
°¡¾Ð¼ö½Ä Áß ÁýÁøÈ¿À²ÀÌ °¡Àå ³ôÀº (5§±âÁØ 99.0%) |
|
ºÐÁø ºÐ¸® ÇÑ°è(50% ºÐ¸®) ÀÔÀÚ°æÀÌ 0.1§·Î ¹Ì¼¼ ºÐÁø ¹ß»ý Áö¿ª¿¡ ÀûÇÕ |
|
¼¼Á¤¼ö´Â ÆßÇÁ¿¡ ÀÇÇÏ¿© Àç»ç¿ë µÇ¸ç ½º·ÎÆ®ºÎÀÇ ¾Ð·Â ¼Õ½ÇÀº 200 ~ 800 mmAq·Î ´Ù¼Ò ³ôÀ½ |
|
|
|
Àû¿ëºÐ¾ß |
|
ÈÇÐ °øÀå, ºñ·á °øÀå, ½ÃÇ° Á¦Á¶ °øÁ¤, »ç·á °øÀå, ¼Ò°¡·ÎÀÇ ¹Ì¼¼ ºÐÁø, Silver Recovery, ±âŸ 0.1 §ÀÌ»óÀÇ ¹Ì¼¼ ºÐÁø ¹ß»ýó |
|
SPECIFICATION |
Model |
Process
rate
(§©/min) |
Blower
pressure
(mmAq) |
Rotation pump |
Body size |
rate
(L/min) |
Power
(kw) |
Dia
(mm) |
H
(mm) |
HSVS-10 |
100 |
220 |
250~300 |
2.2 |
300 |
2000 |
HSVS-15 |
150 |
260 |
380~450 |
3.7 |
300 |
2000 |
HSVS-20 |
200 |
300 |
500~600 |
5.5 |
310 |
2200 |
HSVS-25 |
250 |
320 |
600~750 |
7.5 |
320 |
2300 |
HSVS-30 |
300 |
360 |
800~900 |
7.5 |
350 |
2700 |
HSVS-35 |
350 |
400 |
900~1050 |
11 |
370 |
2700 |
HSVS-40 |
400 |
420 |
1000~1200 |
11 |
400 |
3000 |
HSVS-45 |
450 |
460 |
1200~1350 |
11 |
400 |
3000 |
HSVS-50 |
500 |
500 |
1350~1500 |
15 |
420 |
3800 |
HSVS-60 |
600 |
540 |
1600~18000 |
20 |
450 |
4000 |
|
|
¡Ü »ó±âÇ¥ÀÇ ¼öÄ¡´Â °æÇè ¹× ÇöÀå ¿©°Ç¿¡ µû¶ó ´Þ¶óÁú ¼ö ÀÖÀ½ |
|
|